background image

Status Conditions and Sense Code Information 317

M

a

na
ging

the

Di
sk
Array

on HP-UX

Status Conditions and Sense Code Information

The following tables may be useful interpreting the various types of disk array status
information that is returned by the management tools. Where appropriate, any required
action is identified.

LUN Status Conditions

The LUN status condition terminology used by Array Manager 60 (AM60) may differ from
that used by STM. Both terms are identified in the table.

Table 40

LUN Status Conditions

Status

Definition/Action

AM60: OPTIMAL
STM: OPTIMAL

The LUN is operating normally.
No action is required.

AM60: OPTIMAL--PARITY SCAN
IN PROGRESS
STM: OPTIMAL

A parity scan is in progress on the disk array.
No action is required.

AM60: OPTIMAL-REDUNDANCY
RE-INITIALIZATION PENDING OR
IN PROGRESS
STM: OPTIMAL

A background parity sync operation is in progress on this
LUN.
No action is required. The LUN can be used immediately.

AM60: DEGRADED--WAITING
FOR REPAIR ACTION
STM: DEGRADED - 1

A disk has failed and there is no hot spare to perform a
rebuild.
Replace the failed disk or add a hot spare.

AM60: DEGRADED--REPLACED
DISK BEING FORMATTED
STM: DEGRADED - 65

A disk has been replaced and is being formatted prior to
starting a rebuild on this LUN.
No action is required.