HP Surestore Disk Array 12h and FC60 User Manual

Page 389

background image

Disk Enclosure Modules 389

Re
m

o

v

a

l a
n

d

R

ep
lac
eme

n

t

Note

If the disk module you are installing has been removed from another Disk Array
FC60, you should ensure that the module has a status of Unassigned. This is
done by unbinding the LUN the disk module was a part of in the original disk
array. See

"Moving Disks from One Disk Array to Another" on page 255

.

1. Remove the replacement disk from its ESD bag, being careful to grasp the disk by its

handle (A in

Figure 96

).

2. Pull the cam latch (B) away from the disk module.

3. Mark the slot number that the disk is being installed into on the Slot Location Map on

the top of the disk module. See

Figure 95

. This facilitates reinstalling the disk module in

the correct slot.

Figure 95

Disk Slot Identification Label

Note

Use both hands to hold the disk — one on the handle and the other on the
carrier frame.

4. Slide the disk module into the slot with capacity label up (C in

Figure 96

).

Mark Slot