beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 343

background image

Status Conditions and Sense Code Information 343

M

a

na
ging

the

Di
sk
Array

on HP-UX

A6

00

Recovered processor memory failure

The controller has detected and corrected a recoverable error
in processor memory.

A7

00

Recovered data buffer memory error

The controller has detected and corrected a recoverable error
in the data buffer memory.

Sense bytes 34-36 will contain the count of errors encountered
and recovered

C0

00

The Inter-controller Communications Have Failed

The controller has detected the failure of the communications
link between redundant controllers.

D0

06

Drive IO Time-out

The controller destination IO timer expired while waiting for a
drive command to complete.

D1

0A

Drive Reported Busy Status

A drive returned a busy status in response to a command.

E0

XX

Destination Channel Error

XX = 00 through 07 indicates the Sense Key returned by the
drive after a check condition status

XX = 10 indicates that a bus level error occurred

Table 44

SCSI Sense Codes (cont’d)

Additional
Sense
Code

Additional
Sense Code
Qualifier

Interpretation