Figure 88 – HP Surestore Disk Array 12h and FC60 User Manual
Page 284
284 Managing the Disk Array Using Array Manager 60
Figure 88
Disk Array Sample Status Output (amdsp)
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
Array State = READY
Server name = speedy
Array type = 3
Mfg. Product Code = 348-0040789
--- Disk space usage --------------------
Total physical = 271.4 GB
Allocated to LUNs = 135.4 GB
Used as Hot spare = 0.0 GB
Unallocated (avail for LUNs) = 0.0 GB
-----------------------------------------
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
LUN Status Capacity Ctrl RAID Segment Disks
--- ----------------- --------- ---- ---- ------- -----
0 OPTIMAL 16.9 GB A 1 4 1:0
3:0
1 OPTIMAL 16.9 GB B 1 4 2:0
4:0
.
.
31 UTM:GOOD
LUN WCE RCD CME CWOB WCA RCA CMA
--- --- --- --- ---- --- --- ---
0 X X X X X
1 X X X X X
.
.
.
Total capacity of LUNs on controller A = 84.6 GB
Total capacity of LUNs on controller B = 50.8 GB
Total capacity of all configured LUNs = 135.4 GB
Cache Status for each LUN - all LUNs should
have the status values shown
LUN Information - the
status of each LUN should
be OPTIMAL
LUNs should typically be distributed
between both controllers for best
performance. LUN ownership can be
reassigned to balance LUN usage.
LUN 31 is the default UTM LUN. GOOD status indicates the UTM is
enabled and operating normally. See note on page 283.