Scsi sense codes – HP Surestore Disk Array 12h and FC60 User Manual
Page 327
Status Conditions and Sense Code Information 327
M
a
na
ging
the
Di
sk
Array
on HP-UX
SCSI Sense Codes
lists the SCSI sense codes that may be returned as part of the log entry. This
information may be helpful interpreting log entries. Only the Additional Sense Code and
Additional Sense Code Qualifier fields are required to identify each condition.
Table 44
SCSI Sense Codes
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation
00
00
No Additional Sense Information
The controller has no sense data available for the requesting
host and addressed logical unit combination.
04
01
Logical Unit is in the Process of Becoming Ready
The controller is executing its initialization functions on the
addressed logical unit. This includes drive spinup and validation
of the drive/ logical unit configuration information.
04
02
Logical Unit Not Ready, Initializing Command Required
The controller is configured to wait for a Start Stop Unit com-
mand before spinning up the drives, but the command has not
yet been received.
04
04
Logical Unit Not Ready, Format In Progress
The controller previously received a Format Unit command
from an initiator, and is in the process of executing that com-
mand.
04
81
Storage Module Firmware Incompatible - Manual Code Syn-
chronization Required
04
A1
Quiescence Is In Progress or Has Been Achieved