beautypg.com

Scsi sense codes – HP Surestore Disk Array 12h and FC60 User Manual

Page 327

background image

Status Conditions and Sense Code Information 327

M

a

na
ging

the

Di
sk
Array

on HP-UX

SCSI Sense Codes

Table 44

lists the SCSI sense codes that may be returned as part of the log entry. This

information may be helpful interpreting log entries. Only the Additional Sense Code and
Additional Sense Code Qualifier fields are required to identify each condition.

Table 44

SCSI Sense Codes

Additional
Sense
Code

Additional
Sense Code
Qualifier

Interpretation

00

00

No Additional Sense Information

The controller has no sense data available for the requesting
host and addressed logical unit combination.

04

01

Logical Unit is in the Process of Becoming Ready

The controller is executing its initialization functions on the
addressed logical unit. This includes drive spinup and validation
of the drive/ logical unit configuration information.

04

02

Logical Unit Not Ready, Initializing Command Required

The controller is configured to wait for a Start Stop Unit com-
mand before spinning up the drives, but the command has not
yet been received.

04

04

Logical Unit Not Ready, Format In Progress

The controller previously received a Format Unit command
from an initiator, and is in the process of executing that com-
mand.

04

81

Storage Module Firmware Incompatible - Manual Code Syn-
chronization Required

04

A1

Quiescence Is In Progress or Has Been Achieved