beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 93

background image

3. Creating an HDLM Environment

71

Re-installation in 3.5.5 Performing an Upgrade Installation or Re-installation of

HDLM.

„

If you upgrade or re-install HDLM before you resolve a path failure, LU

reservations might persist without being released. In such a case, use the utility

for clearing HDLM persistent reservations (

dlmpr

) to release the LU reservation,

if necessary.

„

Performing an upgrade installation or re-installation might change the physical

volume (hdisk name). For this reason, you must check and, if necessary, revise

relevant settings, such as the settings for applications that directly access a hard

disk recognized as an HDLM management-target device. Use the output

information of the

view

operation (with the

-drv

parameter) to check the

correspondence between the hdisk and the LU.

3.4.3 Notes on the Virtual I/O Server

„

Before you install HDLM, change the ioslevel version of the virtual I/O server to

a version supported by HDLM. For details about the ioslevel versions supported

by HDLM, see 3.1.3 Cluster Software Supported by HDLM.

„

If you want to apply a virtual SCSI disk to a client partition in a virtual I/O server

environment, install HDLM into the virtual I/O server partition. If you want to

apply a virtual HBA to a client partition, install HDLM into the client partition.

„

Specify an hdisk, or a logical volume configured for HDLM, as the virtual target

device. For details about how to configure a virtual target device, see the

installation procedure in 3.5.3 Performing a New Installation of HDLM and

3.5.5 Performing an Upgrade Installation or Re-installation of HDLM.

„

To set up a virtual SCSI disk MPIO configuration in a client partition, or to use

HACMP in a client partition, set the hdisk reservation policy in the virtual I/O

server partition to

no_reserve

.

„

If you want to use HDLM in a client partition to which a virtual HBA is applied

by using the virtual I/O server NPIV functionality, set the NPIV option to

on

. If

the option is not set to

on

, HDLM might not be able to recognize a path that goes

through the virtual HBA.
To set the NPIV option, execute the

dlmodmset

utility. For details on this utility,

see 7.7 dlmodmset Utility for Setting the HDLM Execution Environment ODM.
If the HDLM device has already been configured, and NPIV option settings are

changed, stop and restart the host. For a local boot disk environment, instead of

stopping and restarting the host, you can also perform the following procedure:
1.

Execute the

dlmrmdev

utility for deleting HDLM drivers to change the

HDLM device status to

Defined

, or delete the HDLM driver.

For details on the

dlmrmdev

utility, see 7.11 dlmrmdev Utility for Deleting