beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 115

background image

3. Creating an HDLM Environment

93

21. Verify that the settings for the parent device (

fscsi

n) are enabled.

Also, verify that the

fc_err_recov

setting has been changed to

fast_fail

.


# lsattr -El fscsin
fc_err_recov fast_fail FC Fabric Event Error RECOVERY Policy
TRUE

22. Enable the defined parent device (

fscsi

n).


# cfgmgr -l fscsi

n

23. Repeat steps 19 to 22 for each parent device (

fscsi

n) being used.

24. Execute the

chdev

command, as required, to change the attributes of the hdisk:


# chdev -l

hdisk-name

-a queue_depth=8 -a rw_timeout=60

25. Execute one of the following commands, as required, to add

/usr/

DynamicLinkManager/bin

to the

PATH

environment variable.

When using a Bourne shell or Korn shell:

# PATH=$PATH:/usr/DynamicLinkManager/bin

# export PATH

When using a C shell:

# set path=( $path /usr/DynamicLinkManager/bin )


To simplify command execution, you can temporarily add the

PATH

environment

variable. To execute HDLM commands or the HDLM utility without setting the

PATH

environment variable, specify an absolute path to execute the commands.

26. Make sure that hdisks are available:


# lsdev -Cc disk
hdisk0 Available 1S-08-00-8,0 16 Bit LVD SCSI Disk Drive
hdisk1 Available 1S-08-00-9,0 16 Bit LVD SCSI Disk Drive
hdisk2 Available 1S-08-00-10,0 16 Bit LVD SCSI Disk Drive
hdisk3 Available 1H-08-02 Hitachi Disk Array (Fibre)
hdisk4 Available 1H-08-02 Hitachi Disk Array (Fibre)
...