8. Messages
357
the
DLMgetras
utility, see 7.2 DLMgetras Utility for Collecting HDLM
Error Information.
KAPL01021-E
Cannot execute the HDLM command due to insufficient memory.
Details
Memory required for HDLM command processing could not be allocated.
Action
Terminate unneeded applications to increase the amount of free memory, and then
retry.
KAPL01023-W
The last Online path for the device cannot be placed Offline(C).
Details
The path specified in the
offline
operation cannot be placed in the
Offline(C)
status because it is the last path for the applicable logical unit.
Action
Use the
view
operation of the HDLM command (
dlnkmgr
) to check the status
of the paths. For details on the
view
operation, see 6.7 view (Displays
Information).
KAPL01024-W
The specified parameters cannot be specified at the same time.
Operation name =
aa...aa
, parameters =
bb...bb
Details
aa...aa:
clear
,
offline
,
online
,
set
, or
view
bb...bb:Parameters that cannot be specified at the same time
Action
Execute
help
operation of the HDLM command (
dlnkmgr
) to check which
parameters can be specified at the same time, and then retry. For details on the
help
operation, see 6.3 help (Displays the Operation Format).
KAPL01036-E
The Offline path cannot be placed online. PathID =
aa...aa
Details
aa...aa: Path ID (decimal (base-10) number)
Action