2 requirements for outputting audit log data – HP Hitachi Dynamic Link Manager Software User Manual
Page 70

2. HDLM Functions
48
#1
The severity levels are as follows:
3: Error, 4: Warning, 6: Informational
#2
If you use Ctrl + C to cancel the
DLMgetras
utility for collecting HDLM error
information, audit log data indicating that the
DLMgetras
utility has terminated
will not be output.
#3
If you use Ctrl + C to cancel the
dlmgetrasinst
utility for collecting HDLM
installation error information, audit log data indicating that the
dlmgetrasinst
utility has terminated will not be output.
2.11.2 Requirements for Outputting Audit Log Data
HDLM can output audit log data when all of the following conditions are satisfied:
• The
syslog
daemon is active.
• The output of audit log data has been enabled by using the HDLM command's
set
operation.
However, audit log data might still be output regardless of the above conditions if, for
example, an HDLM utility is executed from external media.
#
#:
The following audit log data is output:
• Categories:
StartStop
,
Authentication
, and
ConfigurationAccess
• Severity: 6 (Critical, Error, Warning, or Informational)
• Destination: syslog (facility value:
user
)
Note:
• Enable
syslog
since
syslog
is disabled by default in AIX.
Processing of the
dlmchpdattr -a
command was successful.
6
KAPL15082-I
Processing of the
dlmchpdattr -a
command failed.
3
KAPL15083-E
Category
Explanation
Audit event
Severity
#1
Message ID