3. Creating an HDLM Environment
143
(10) Setting the Number of Trace Files
You can set the number of the trace files.
Trace files for which the number of files can be set are
hdlmtr
n
.log
(n indicates a
file number from
1
to
64
).
For the number of the trace files, you can specify a value from 2 to 64. If you specify
a value smaller than the value that has already been specified, the KAPL01097-W
message will be displayed to confirm the execution, and the trace file will be
temporarily deleted.
By specifying both the trace file size and the number of trace files, you can collect up
to 1024000KB of trace data.
The following is an example of setting up the number of trace files by using a
command:
# /usr/DynamicLinkManager/bin/dlnkmgr set -systfn 10
Specify the number of trace files by using numbers.
(11) Setting Up Audit Log Data Collection
You can set whether to collect audit log data.
If you want to collect audit log data, you must also specify the collection level for audit
log data and the audit log categories.
Table 3-17: Values Indicating Audit Log Data Collection Levels describes the values
that indicate audit log data collection levels. An audit log data collection level is a
severity level. The default is
6
.
Table 3-17: Values Indicating Audit Log Data Collection Levels
Value (severity)
Explanation
0
No audit log data is collected.
1
2
Critical-level audit log data is collected.
3
Critical-level and Error-level audit log data is collected.
4
Critical-level, Error-level, and Warning-level audit log data is collected.
5
6
Critical-level, Error-level, Warning-level, and Informational-level audit log data is
collected.