beautypg.com

Viewing drive cage power supply details – HP 3PAR Operating System Software User Manual

Page 313

background image

The following information is provided:

Description

Column

Physical disk ID, as assigned by the system. For unadmitted disks, this columns is blank
(--).

ID

Location of the disk in C:M:D (Cage:Magazine:Disk) format..

Position

The World Wide Name (WWN) assigned to the disk.

WWN (for non-SAS drives)

The device name assigned to the disk.

WWN/Device Name (for DCS1
and DCS2 drive cages)

Current state of the disks.

Status LED (for DC1, DC2, and
DC4 drive cages)

Current internal temperature of the disk drive.

Temperature

The loop A arbitrated loop physical address of the disk.

Loop A AL_PA

Status of the Interface Card loop to the node. See

“System and Component Status

Icons” (page 409)

.

Loop A State

The loop B arbitrated loop physical address of the disk.

Loop B AL_PA

Status of the Interface Card loop to the node. See

“System and Component Status

Icons” (page 409)

.

Loop B State

Status of the physical disk. See

“System and Component Status Icons” (page 409)

.

State (for DCS1 and DCS2
drive cages).

Viewing Drive Cage Power Supply Details

To view power supply details:
1.

Access the Drive Cages screen.

2.

In the list pane of the Drive Cages screen, click the Summary tab and then click a drive cage.

3.

In the detail pane, click the Power Supplies tab.

The Power Supplies tab appears as follows (the following image depicts information for a DC2
drive cage. Your screen may differ depending on the drive cage type in your system):

Viewing Drive Cages

313

This manual is related to the following products: