The following information for DC1 drive cages is provided:

Description

Column

The interface card name.

Name

Ports for each FC-AL. For FC-AL A, that is A0 and A1, and for FC-AL B, that is B0
and B1.

Ports

Current state of port 0.

Loop LED (Port 0)

Current state of port 1.

Loop LED (Port 1)

Current state of daisy-chained drive cages (Unknown, Normal, Off, Green, Green
blink, Amber, Amber blink).

Loop Split

Current state of interface card.

Status LED

Link speed.

Link Speed

Drive cage firmware status (Current, Not Current, Unknown).

Firmware State

Current state of the current loop's CPU (Unknown, Normal, Failed, Degraded).

CPU State (Self)

Current state of other loop's CPU (Unknown, Normal, Failed, Degraded).

CPU State (Partner)

The following information for DCS1 and DCS2 drive cages is provided:

Description

Column

The interface card name.

Name

Ports for each FC-AL. For FC-AL A, that is A0 and A1, and for FC-AL B, that is B0
and B1.

Ports

Current state of port A.

Port A State

Current state of port B.

Port V State

Link speed of port A (in Gbps).

Port A Link Speed

Link speed of port B (in Gbps).

Port B Link Speed

Drive cage firmware status (Current, Not Current, Unknown).

Firmware State

Current state of the cage.

State

Viewing the Drive Cage Magazine Details

To view drive magazine details:
1.

Access the Drive Cages screen.

2.

In the list pane of the Drive Cages screen, click the Summary tab and then click a drive cage.

3.

In the detail pane, click the Magazines tab.

The Magazine tab appears as follows (the following image depicts information for a DC2 drive
cage. Your screen may differ depending on the drive cage type in your system):

Viewing Drive Cages