Viewing drive cage connectivity – HP 3PAR Operating System Software User Manual
Page 302
Description
Column
The number of disks in the drive cage. The bottom of the Disks column displays
a total disk count.
Disks
The total Fast Class capacity in GiB. The bottom of the FC Total column displays
total FC capacity for all cages.
FC Total
The percentage of used Fast Class capacity. The bottom of the FC Allocated
Percentage column displays the total used percentage.
FC Allocated Percentage
The total NL capacity, in GiB. The bottom of the NL Total column displays total
FC capacity for all cages.
NL Total
The percentage of used NL capacity.
NL Allocated Percentage
The total SSD capacity in GiB. The bottom of the SSD Total column displays total
SSD capacity for all cages.
SSD Total
The percentage of used SSD capacity. The bottom of the SSD Allocated Percentage
column displays the total used percentage.
SSD Allocated Percentage
NOTE:
The device types displayed in the summary are dependent on the devices installed in your system. For
example, if you have Near Line and disk drives installed, the summary will display NL (Near Line) Total, NL Allocated
Percentage columns.
The Summary tab can be further filtered to view drive cage connectivity and drive cage capacity.
“Viewing Drive Cage Connectivity” (page 302)
“Viewing Drive Cage Capacity” (page 303)
Viewing Drive Cage Connectivity
To view drive cage connectivity information, select Connectivity from the filter list.
The following information is provided:
Description
Column
The drive cage ID.
ID
The drive cage name.
Name
The drive cage state. See
“System and Component Status Icons” (page 409)
.
State
Distance the drive cage is from the controller node port. (0 = directly connected to
system ports, 1= there is one device between the node and this drive cage, etc).
Position A
Version of firmware running on the controller for the A loop.
Revision A
Distance the drive cage is from the controller node port. (0 = directly connected to
system ports, 1= there is one device between the node and this drive cage, etc).
Position B
Version of firmware running on the controller for the B loop.
Revision B
Controller node initiator port connected to drive cage port A0.
A0 Port
Controller node initiator port connected to drive cage port A1.
A1 Port
302 Managing Drive Cages