IAI America E-Con User Manual
Page 71

63
4. XSEL-R/S/RX/SX/RXD/SXD
[3] CC-Link Board Use Setting
Set “1” (Monitoring: use CC-Link board) to I/O Parameter No. 235.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
235
Network I/F Module Error
Monitoring
1
0 to 5
-
0: No Monitoring
(Not to monitor condition of link
to PLC (master))
1: Monitoring
[4]
Node
address
setting
Set the node address to I/O Parameter No. 237
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
237
Network I/F Module 2
Node Address
0
0 to 64
-
CC-Link node address range:
1 to 64
Note If
a
number
out of the settable range is selected, “D75: Fieldbus Parameter Error” will
occur.
[5] Communication
Speed Setting
Set the communication speed in I/O Parameter No. 238. Match the setting to the communication
speed of the master unit.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
238
Network I/F Module 2
Baud rate
0
0 to 4
-
0: 156Kbps
1: 625Kbps
2: 2.5Mbps
3: 5Mbps
4: 10Mbps
Note If a number out of the settable range is selected, “D75: Fieldbus Parameter Error” will
occur.
[6] Number of I/O Port Setting
Set the number of ports to be used for I/O Parameters No. 231 to 232.
Note Set a number that is a multiple of 8.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
231
Network I/F Module 2
Remote Input Ports
0
0 to 256
-
8 port unit
232
Network I/F Module 2
Remote Output Ports
0
0 to 256
-
8 port unit
Network I/F Module 2 Error
Monitoring
Node Address Setting
Baud Rate Setting
Network I/F Module 2
Baud Rate
No. of Network I/F Module 2
Remote Input Ports
No. of Network I/F Module 2
Remote Output Ports