IAI America E-Con User Manual
Page 101

93
5. T
abletop Robot TT
(3)
When the number of I/O points is set to 208 or more and 256 or less:
Configured as three remote devices. (Three stations occupied)
I/O parameter
No. 14 No. 15
TT side DI
(Port No.)
PLC side
TT side DO
(Port No.)
PLC side
(16) (16)
048-063
RY
0 – F
348 - 363
RX
0 – F
(32) (32)
064-079
RY 10
–
1F 364 - 379
RX 10
–
1F
(48) (48)
080-095
RY
20
–
2F
380 - 395
RX
20
–
2F
(64) (64)
096-111
RY
30
–
3F
396 - 411
RX
30
–
3F
(80) (80)
112-127
RY
40
–
4F
412 - 427
RX
40
–
4F
(96) (96)
128-143
RY
50 – 5F
428 - 443
RX
50 – 5F
(112) (112)
144-159
RWw 0
444 - 459
RWr 0
(128) (128)
160-175
RWw 1
460 - 475
RWr 1
(144) (144)
176-191
RWw 2
476 - 491
RWr 2
(160) (160)
192-207
RWw 3
492 - 507
RWr 3
(176) (176)
208-223
RWw 4
508 - 523
RWr 4
(192) (192)
224-239
RWw 5
524 - 539
RWr 5
208 208
240-255
RWw 6
540 - 555
RWr 6
224 224
256-271
RWw 7
556 - 571
RWr 7
240 240
272-287
RWw 8
572 - 587
RWr 8
Not be set
-
RWw 9
-
RWr 9
Not be set
-
RWw A
-
RWr A
Not be set
-
RWw B
-
RWr B
* Since the shaded portions are the system areas for the remote device station on the PLC side, they
cannot be used as I/O.
* In the case of three stations being occupied, twelve words (nine words for TT) are assigned for each
input and output in the data register on the PLC side. Be careful about overlapping of data register on
the PLC side.