2) factory-configured parameters – IAI America E-Con User Manual

Page 59

background image

51

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

(2) Factory-configured

parameters

A: X-SEL-K

ṅ-ṅ-CC1-ṅ

B: X-SEL-K

ṅ-ṅ-CC2-ṅ

C: X-SEL-K

ṅ-ṅ-CC3-ṅ

Set

value

No. Parameter

name

Input

range

A B C

Remarks

1

I/O port assignment type

0 – 20

0

0

0

0: Fixed assignment

1: Automatic assignment (Priority: slot 1

᫦)

* The ports only in the continuous installation

range from slot 1 are assigned for safety.)

2

Standard I/O fixed assignment time:

Input port start No. (I/O 1)

-1 – 599

-1

-1

-1

0 + (multiples of 8) (Invalid for negative values)

3

Standard I/O fixed assignment time:

Output port start No. (I/O 1)

-1 – 599

-1

-1

-1

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

-1 – 599

-1

-1

032

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

-1 – 599

-1

-1

332

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

-1 – 599

-1

016

016

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

-1 – 599

-1

316

316

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

-1 – 599

0

0

0

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

-1 – 599

300

300

300

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring

(I/O 1)

0 – 5

0

0

0

11

Expansion I/O 1 error monitoring

(I/O 2)

0 – 5

0

0

2

12 Expansion I/O 2 error monitoring

(I/O 3)

0 – 5

0

2

2

13 Expansion I/O 3 error monitoring

(I/O 4)

0 – 5

2

2

2

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power related

errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote: Number of

ports used for input

0 – 256

0

0

0

Multiples of 8

15 Network I/F card remote: Number of

ports used for output

0 – 256

0

0

0

Multiples of 8

(I/O 1) to (I/O 4) indicate the slot numbers.

(Note) When a standard I/O board is not used, it is not required to supply 24V DC to the I/O 24V power connector. In this case,

set the parameter No. 10 to “0.”