X-sel i/o parameter – IAI America E-Con User Manual
Page 64

56
3. X-SEL-J/K/P/Q/JX/KX/PX/QX
X-SEL I/O parameter
No. Parameter
name
Default
(reference)
Input
range
Setting Remarks
1
I/O port assignment type
0
0 – 20
0
0: Fixed assignment
1: Automatic assignment (Priority: slot 1
)
* The ports only in the continuous
installation range from slot 1 are
assigned for safety.)
2
Standard I/O fixed assignment
time:
Input port start No. (I/O 1)
-1
-1 – 599
000
0 + (multiples of 8) (Invalid for negative values)
3
Standard I/O fixed assignment
time:
Output port start No. (I/O 1)
-1
-1 – 599
300
300 + (multiples of 8)
(Invalid for negative values)
4
Expansion I/O 1 fixed assignment
time: Input port start No. (I/O 2)
032
-1 – 599
032
0 + (multiples of 8) (Invalid for negative values)
(Slot next to the standard I/O)
5
Expansion I/O 1 fixed assignment
time: Output port start No. (I/O 2)
332
-1 – 599
316
300 + (multiples of 8)
(Invalid for negative values)
6
Expansion I/O 2 fixed assignment
time: Input port start No. (I/O 3)
016
-1 – 599
048
0 + (multiples of 8) (Invalid for negative values)
7
Expansion I/O 2 fixed assignment
time: Output port start No. (I/O 3)
316
-1 – 599
332
300 + (multiples of 8)
(Invalid for negative values)
8
Expansion I/O 3 fixed assignment
time: Input port start No. (I/O 4)
000
-1 – 599
064
0 + (multiples of 8) (Invalid for negative values)
9
Expansion I/O 3 fixed assignment
time: Output port start No. (I/O 4)
300
-1 – 599
348
300 + (multiples of 8)
(Invalid for negative values)
10 Standard I/O error monitoring (I/O
1)
0
0 – 5
1
11 Expansion I/O 1 error monitoring
(I/O 2)
2
0 – 5
2
12 Expansion I/O 2 error monitoring
(I/O 3)
2
0 – 5
2
13 Expansion I/O 3 error monitoring
(I/O 4)
2
0 – 5
2
0: Non-monitoring
1: Monitoring
2: Monitoring (Non-monitoring of 24V I/O
power related errors)
(Main application of Ver. 0.55 or later)
3: Monitoring (Monitoring of 24V I/O power
related errors only)
(Main application of Ver. 0.55 or later)
14 Network I/F card remote:
Number of ports used for input
0
0 – 256
0
Multiples of 8
15 Network I/F card remote:
Number of ports used for output
0
0 – 256
0
Multiples of 8
(I/O 1) to (I/O 4) indicate the slot numbers.