28

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

X-SEL P/Q type controller I/O parameter

No. Parameter

name

Default

(reference)

Input

range

Setting Remarks

1

I/O port assignment type

0

0 – 20

0

0: Fixed assignment

1:

Automatic

assignment (Priority: Network

I/F module

o slot 1 (Standard I/O) -, *

The ports only in the continuous

installation range from slot 1 are

assigned for safety.)

2

Standard I/O fixed assignment time:

Input port start No. (I/O 1)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

3

Standard I/O fixed assignment time:

Output port start No. (I/O 1)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

-1

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

-1

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring

(I/O 1)

0

0 – 5

0

11

Expansion I/O 1 error monitoring

(I/O 2)

0

0 – 5

0

12 Expansion I/O 2 error monitoring

(I/O 3)

0

0 – 5

0

13 Expansion I/O 3 error monitoring

(I/O 4)

0

0 – 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power

related errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote:

Number of ports used for input

64

0 – 256

16

Multiples of 16

15 Network I/F card remote:

Number of ports used for output

64

0 – 256

16

Multiples of 16

16 Network I/F module fixed

assignment time: Number of ports

used for input

0

-1-599

0

0+ (multiple of 8) (Invalid for negative values)

17 Network I/F module fixed

assignment time: Number of ports

used for input

300

-1-599

300

300+ (multiple of 8) (Invalid for negative values)

18 Network I/F module error monitoring

1

0-5

1

0: Non-monitoring

1: Monitoring

* Some exceptions included.

(I/O 1) to (I/O 4) indicate the slot numbers.