IAI America E-Con User Manual
Page 135

127
8.
ASEL, PSEL, SSEL
(3)
In the case that I/O Points setting is larger than 208 and smaller than 256 points:
They are configured as three remote devices (No. of Occupied Stations: Three Stations)
I/O Parameter
No.14 No.15
DI on the ASEL,
PSEL and SSEL
Side
PLC Side
DO on the ASEL,
PSEL and SSEL
Side
PLC Side
(16)
(16)
000 – 015
RY
0 – F
300 – 315
RX
0 – F
(32)
(32)
016 – 031
RY
10 – 1F
316 – 331
RX
10 – 1F
(48)
(48)
032 – 047
RY
20 – 2F
332 – 347
RX
20 – 2F
(64)
(64)
048 – 063
RY
30 – 3F
348 – 363
RX
30 – 3F
(80)
(80)
064 – 079
RY
40 – 4F
364
379
RY
40 – 4F
(96) (96)
080 – 095
RY
50 – 5F
380
395
RY
50 – 5F
(112)
(112)
096 – 111
RWw0
396 – 411
RWr0
(128)
(128)
112 – 127
RWw1
412 – 427
RWr1
(144)
(144)
128 – 143
RWw2
428 – 443
RWr2
(160)
(160)
144 – 159
RWw3
444 – 459
RWr3
(176)
(176)
160 – 175
RWw4
460 – 475
RWr4
(192)
(192)
176 – 191
RWw5
476 – 491
RWr5
208
208
192 – 207
RWw6
492 – 507
RWw6
224
224
208 – 223
RWw7
508 – 523
RWw7
240
240
224 – 239
RWw8
524 – 539
RWw8
256
256
240 – 255
RWw9
540 – 555
RWw9
Impossible setting
℞℣⅃ℍ
℞℣ℾℍ
Impossible setting
℞℣⅃B
℞℣⅃B
* The ports in gray column show the system domain for the remote device station on the PLC side, so any of them can
not be used as an I/O port.
* In the case of three occupied stations, 12 words for each input and output are allocated for the data register on the PLC side
(10 words for ASEL, PSEL and SSEL). Take care of the duplicated use of the data registers on the PLC side.
The ports in gray column show the system area for the remote device station on the PLC side, so any of them can