IAI America E-Con User Manual
Page 133

125
8.
ASEL, PSEL, SSEL
ASEL, PSEL and SSEL Network Related I/O Parameter List
No. Parameter
Name
Set Value in
Unit Delivery
Input Range
Remarks
1 I/O
Port
Allocation
Type
0
0
–
20
0: Fixed Allocation
1: Automatic Allocation
14
No. of Network I/F Module
Remote Input Ports
128
0
–
256
Multiples of 8
15
No. of Network I/F Module
Remote Output Ports
128
0
–
256
Multiples of 8
16
Input Port Start No. in Network I/F
Module Fix-Allocation
0
-1
–
599
0 + (Multiples of 8)
(Unavailable when it is negative figure)
17
Output Port Start No. in Network
I/F Module Fix-Allocation
300
-1
–
599
300 + (Multiples of 8)
(Unavailable when it is negative figure)
18
Network I/F Module Error
Monitoring
1
0
–
5
0: Non Monitoring
1: Monitoring
* When a network link error continues
for more than the network link error
confirmation timer set value, it is
regarded as a system error. (Refer to
I/O parameter No. 120).
* There are some exceptions
120
Network Attribute 1
1H
0H
–
FFFFFFFFH
Bit 0 to 3: System Reservation
Bit 4 to 11: Network Link Error
Confirmation Timer Value (Setting Units
of 10 msec)
Only when I/O Parameter No. 18 is set
to “1H”, it is available.
(Example)
When the set value (Bit 4 to 11) is
“05H”, the timer time value becomes
“10 ms x 5 = 5ms”.
Also, when the set value is “0H”, the
network link error occurs and it is
regarded as a system error.
225
Network I/F Module Control
1H
For reference
only
Bit 0 to 3: Network I/F Module Type
(0: Not Mounted, 1: CC-Link Module, 2:
DeviceNet Module)
226
Network I/F Module
Communication Attribute 1
1
0
999
Network I/F Module Node Address
* In the case of CC-Link Module: 1 to 64
227
Network I/F Module
Communication Attribute 2
4H
0H
–
FFFFFFFFH
Bit 0 to 3: Network I/F Module Baud
Rate Type
In the case of CC-Link Module:
0℆156Kbps, 1℆625Kbps,
2
℆2.5Mbps, 3℆5Mbps,
4:10Mbps