Overview – IAI America E-Con User Manual
Page 16

8
1. Overview
XSEL-P/Q
XSEL-R/S/RX/SX/RXD/SXD
SCON
SSEL
ACON
ASEL
PCON
PSEL
1. Overview
CC-Link is an abbreviation of Control & Communication Link and is one of the open field network
standards.
IAI controllers shown below are available for the connection to CC-Link.
Note 1 See the other booklet ME0254 CC-Link for more details.
Example for Network Construction
Model Type
Characteristics
XSEL-J/K/P/Q
Remote device station
The X-SEL's I/O data can be processed as bit data or word data.
For each of input and output points, max. 256 points are
available.
XSEL-R/S/RX/SX/
RXD/SXD
Remote device station
The X-SEL's I/O data can be processed as bit data or word data.
For each of input and output points, max. 256 points are
available.
XSEL-K
Remote I/O
This is the remote I/O module with 16 I/O points.
ASEL, PSEL, SSEL
Remote device station
It can be operated as the same as the control with PIO.
TT
Remote device station
The TT's I/O data can be processed as bit data or word data.
For each of input and output points, max. 256 points are
available.
RCS-C, E-CON,
SCON-C
Remote I/O
It can be operated as the same as the control with PIO.
ACON, PCON,
SCON-CA
(Note 1)
Remote device station
In addition to the processing as the same as the operation with
PIO, it can be operated with the target position, speed and
acceleration/deceleration speed directly setup using the values.
Note For the details of CC-Link, refer to the instruction manuals of Master Unit and Programmable Controller
(described as PLC from now).
When reading this Operation Manual, also refer to the Operation Manuals for the ACON and PCON controller
you are using
CC-Link cannot be used for any method other than those described as possible in this Operation Manual.