beautypg.com

IAI America E-Con User Manual

Page 28

background image

20

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

(3)

Factory-configured parameters of P/Q type

No. Parameter

name

Input

range

Set

value

Remarks

1

I/O port assignment type

0 – 20

1

0: Fixed assignment

1: Automatic assignment (Priority: Network I/F

module

o slot 1 (Standard I/O) -,

* The ports only in the continuous installation

range from slot 1 are assigned for safety.)

2

Standard I/O fixed assignment time:

Input port start No. (I/O 1)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

3

Standard I/O fixed assignment time:

Output port start No. (I/O 1)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

4

Expansion I/O 1 fixed assignment

time: Input port start No. (I/O 2)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

(Slot next to the standard I/O)

5

Expansion I/O 1 fixed assignment

time: Output port start No. (I/O 2)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

6

Expansion I/O 2 fixed assignment

time: Input port start No. (I/O 3)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

7

Expansion I/O 2 fixed assignment

time: Output port start No. (I/O 3)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

8

Expansion I/O 3 fixed assignment

time: Input port start No. (I/O 4)

-1 – 599

-1

0 + (multiples of 8) (Invalid for negative values)

9

Expansion I/O 3 fixed assignment

time: Output port start No. (I/O 4)

-1 – 599

-1

300 + (multiples of 8)

(Invalid for negative values)

10 Standard I/O error monitoring (I/O 1)

0 – 5

0

11 Expansion I/O 1 error monitoring (I/O

2)

0 – 5

0

12 Expansion I/O 2 error monitoring (I/O

3)

0 – 5

0

13 Expansion I/O 3 error monitoring (I/O

4)

0 – 5

0

0: Non-monitoring

1: Monitoring

2: Monitoring (Non-monitoring of 24V I/O power

related errors)

(Main application of Ver. 0.55 or later)

3: Monitoring (Monitoring of 24V I/O power related

errors only)

(Main application of Ver. 0.55 or later)

14 Network I/F card remote:

Number of ports used for input

0 – 256

64

Multiples of 16

15 Network I/F card remote:

Number of ports used for output

0 – 256

64

Multiples of 16

16 Network I/F module fixed assignment

time: Number of ports used for input

-1-599

0

0+ (multiple of 16) (Invalid for negative values)

17 Network I/F module fixed assignment

time: Number of ports used for output

-1-599

300

300+ (multiple of 16) (Invalid for negative values)

18 Network I/F module error monitoring

0-5 1

0:

Non-monitoring

1: Monitoring
* Some exceptions included.

(I/O 1) to (I/O 4) indicate the slot numbers.

This manual is related to the following products: