Toggle rpm, 46 pls functions – Electro Cam PL-1746 Series User Manual
Page 91

4-46 PLS Functions
Toggle RPM
Backplane
PL-1746 Function Name
SLC 500
Mapping Read/
Valid Range for Data
File
Index
Write
Address
Number
Capability
Toggle RPM
M0:S.50
228
R/W
0-9999
Screen
MAIN SCREEN
to CONFIG MENU
to SECONDARY SETUP
to
TOGGLE RPM
TOGGLE
RPM: 50
Use the numeric keys and ENT to enter a new value, or use INC and DEC to change an
existing value.
Description
Toggle RPM is the resolver speed at which the Position display on the Main Screen will
disappear. At speeds below the Toggle RPM the Position display will be visible; at
speeds above the Toggle RPM the Position will not be shown.