4-17 PLS Functions

Model & Options

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Model

M0:S.0

128

R/O

1746

Options

M0:S.2

132

R/O

0 = Standard, 1 = Shift Register

MAIN SCREEN

to TEST MENU

to SYSTEM INFO MENU

to

MODEL & OPTIONS

PL-1746-C02/3-R1
OPTIONS:STD

Description

This screen displays the model type and the options included (designated by letters).

Motion ANDing

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Motion ANDing

M0:S.512-

1152-

R/W*

0=OFF

Channels 0-31, 1word/channel

M0:S.543

1214

Not while

1=ML1

running

2=ML2

Screen

MAIN SCREEN

to CONFIG MENU

to INITIAL SETUP

to MO-

TION ANDING

CHN: 12
MOTION AND: L1

Channel number
Motion ANDing level: L1, L2, or OFF.
(Toggle with SEL key)

This screen displays the channel number and the motion ANDing limit band for Motion
ANDing: L1, L2, or OFF. The channel will not be Motion ANDed if the enable is OFF.
Select a new channel by pressing the INC/DEC keys, or through direct numeric entry
followed by ENT. Press the SEL key to toggle the ANDing to L1, L2, or OFF.

Description

This function is used to tie the operation of output channels to the motion detection
levels programmed through MOTION ANDING LIMIT BANDS. Each output channel
may be ANDed with either motion ANDing limit band. If an output is Motion ANDed, it
will turn ON only when the resolver RPM is in the range band specified for that motion
ANDing limit band, AND the setpoints progammed for that channel are ON.

Operation
• Any number of output channels can be ANDed to a single Motion Detection level.
• Motion ANDing and Output Enable ANDing can be combined for any given output

channel.

• When Motion ANDing is activated for a channel, it will apply to that channel in all

programs.

Motion Detector
An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.

Outputs that must always operate, regardless of machine speed, should not be ANDed
with a motion ANDing limit band. Also see MOTION DETECTION.