4-19 PLS Functions
Output Enable ANDing
Backplane
PL-1746 Function Name
SLC 500
Mapping Read/
Valid Range for Data
File
Index
Write
Address
Number
Capability
Output Enable ANDing
Channels 0-31, 1bit/channel
M0:S.272-
672-
R/W
0=On
M0:S.273
674
1=Off
Screen
MAIN SCREEN
to CONFIG MENU
to INITIAL SETUP
to
OUTPUT ENABLE ANDING
Select a new channel by pressing INC/DEC, or using the numeric keys followed by
ENT. Use the SEL key to toggle ANDing on and off.
Description
Output Enable ANDing allows you to AND any output channels with the Output Enable
Signal. A channel ANDed with this signal will be enabled to turn on at its programmed
setpoints only while the Output Enable Signal is energized. The signal is the logical OR
of bit 7 in the register at address O.S.0 and PS-4108 rack input 7 (or dc input 7 on the
front panel of C02/C03 models). Note that if output word 0 is mapped to another regis-
ter, its value is ignored (set to zero) and the source for this signal is rack (dc input) input
7 alone.
Also see INPUT STATUS.
Output Assignment
Backplane
PL-1746 Function Name
SLC 500
Mapping Read/
Valid Range for Data
File
Index
Write
Address
Number
Capability
C02,C03 only
Output Assignments
M0:S.600-
1328-
R/W*
0-31
Outputs 0-5, 1word/output
M0:S.605
1338
Not while
running
Screen
MAIN SCREEN
to CONFIG MENU
to INITIAL SETUP
OUTPUT
ASSIGN
OUTPUT: 0
CHANNEL: 0
To select the output to assign or the channel to use for that output, use the numeric
keys and ENT, or use the INC and DEC keys.
Description
The Output Assignment screen allows selection of any channel to drive each of the
front panel output terminals.