2-20 Installation
DIP Switch Settings (cont'd)
PL-1746-C02/C03 DIP Switch Settings (All reserved switches must be OFF)
Switch
ON
OFF
1
Local I/O Module
Remote I/O Module
2
Resolver Mode: Master
Resolver Mode: Slave
3
Connect Termination Resistors Disconnect Termination Resistors
4
Reserved
Reserved
5
Reserved
Reserved
6
Reserved
Reserved
7
Reserved
Reserved
PL-1746-C04 DIP Switch Settings (All reserved switches must be OFF)
Switch
ON
OFF
1
Local I/O Module
Remote I/O Module
2
Resolver Mode: Master
Resolver Mode: Slave
3
Reserved
Reserved
4
Reserved
Reserved
5
Connect Termination Resistors Disconnect Termination Resistors
6
Reserved
Reserved
7
Reserved
Reserved