9-6 Specifications & Factory Defaults
Resolver Specifications
Operating Temp:
-40
°
to 125
°
C (-40
°
to 257
°
F)
Storage Temp:
-40
°
to 125
°
C (-40
°
to 257
°
F)
Operating Humidity:
95% Relative non-condensing
NEMA Rating:
NEMA 4
NEMA 4X
Maximum RPM:
3000 RPM
Max Cable Length:
1000 Ft.
Type:
Single Turn - Brushless
Resolution (all):
12 Bits (4096 increments)
Linearity (standard):
+/-20 arc minutes (resolver only)
(+/-30 arc minutes combined with R/D converter in controller)
Linearity (specials):
+/-3 to +/-10 arc minutes (resolver only)
(+/-7 to +/-14 arc minutes combined with R/D converter in controller)
Note: A resolver’s linearity errors are repeatable at all positions of its 360 degree rotation.
Therefore, once appropriate setpoints are established, machine performance is consistent every cycle.