Pulse copy (cont’d), 28 pls functions – Electro Cam PL-1746 Series User Manual
Page 73
4-28 PLS Functions
Pulse Copy (cont’d)
Example
Generate a train of pulses as follows:
Pulse
On
Off
1
0
50
2
100
150
3
200
250
4
300
350
5
400
450
6
500
550
7
600
650
8
700
750
9
800
850
10
900
950
Each pulse is 50 increments wide, separated from the next pulse by 50 increments.
Description
Pulse Copy allows you to program a series, or “train” of pulses into a channel without
having to enter the On and Off edges for each pulse. The Pulse Copy function prompts
you for the beginning and ending edges for the pulse train; the number of pulses in the
train; and the duration of a pulse. Pulse Copy then divides the designated portion of the
resolver cycle into the specified number of pulses, evenly dividing the unused portion of
the segment between the pulses.
Screens
Menu Path
MAIN SCREEN
to FUNCTION
to PULSE COPY
The Pulse Copy function consists of eight screens:
(continued)
PROGRAM:---<
Program to add pulses to;
Enter number, then SEL to go to next screen
CHANNEL:---<
Channel to add pulses to;
Enter number, then SEL to go to next screen
ON:---<
"On" time of leading edge of first pulse;
Enter number, then ENT & SEL to go to next screen
OFF:---<
"Off" time of trailing edge of last pulse;
Enter number, then ENT & SEL to go to next screen
COUNT---<
Total number of pulses to be added;
Enter number, then ENT & SEL to go to next screen
DURATION:---<
Duration of each pulse added;
Enter number, then ENT & SEL to go to next screen
DURATION: 35
EXECUTE<
Move cursor to EXECUTE, then press SEL to
generate pulses. To review values before executing,
move cursor to top row and press SEL as needed
DURATION: 35
COMPLETE<
COMPLETE indicates pulses have been generated