Program copy (cont'd), 26 pls functions – Electro Cam PL-1746 Series User Manual
Page 71
4-26 PLS Functions
Program Copy (cont'd)
M0:S.770/15
The Error bit is set if any of the above error bits is set. This provides a
single bit to test for command success/failure. When the Error Bit is
set, test the other bits to determine the exact cause.
When the error bit M0:S.770/15 is set, the Command Error bit and the Any Error bit are
set in the Programming Error Register (I:S.7). To clear the error condition, toggle the
Clear Error bit (O:S.0/8) ON. No additional commands will be accepted until the error
bits are cleared.
Screen
MAIN SCREEN
to FUNCTION
to PGM COPY
OUTPUTS 76543210
0-7
00000000
The Program Copy function consists of four screens:
SRC PROGRAM:---<
Program to be copied from
DST PROGRAM:---<
Destination to be copied to
DST PROGRAM: 6<
EXECUTE<
Move cursor to EXECUTE, then press SEL
to copy program
DST PROGRAM: 6
COMPLETE<
COMPLETE indicates program
successfully copied
Use the numeric keys and SEL to enter program numbers.
During programming, the cursor keys allow you to move between the Source and Des-
tination screens to allow you to change values before selecting EXECUTE.
Description
Program Copy allows you to copy all the pulses in the source program to the destination
program. It may be easier to copy an existing program and modify it, than to enter a
completely new program.