beautypg.com

Program copy (cont'd), 26 pls functions – Electro Cam PL-1746 Series User Manual

Page 71

background image

4-26 PLS Functions

Program Copy (cont'd)

M0:S.770/15

The Error bit is set if any of the above error bits is set. This provides a
single bit to test for command success/failure. When the Error Bit is
set, test the other bits to determine the exact cause.

When the error bit M0:S.770/15 is set, the Command Error bit and the Any Error bit are
set in the Programming Error Register (I:S.7). To clear the error condition, toggle the
Clear Error bit (O:S.0/8) ON. No additional commands will be accepted until the error
bits are cleared.

Screen

MAIN SCREEN

to FUNCTION

to PGM COPY

OUTPUTS 76543210
0-7

00000000

The Program Copy function consists of four screens:

SRC PROGRAM:---<

Program to be copied from

DST PROGRAM:---<

Destination to be copied to

DST PROGRAM: 6<

EXECUTE<

Move cursor to EXECUTE, then press SEL
to copy program

DST PROGRAM: 6

COMPLETE<

COMPLETE indicates program
successfully copied

Use the numeric keys and SEL to enter program numbers.
During programming, the cursor keys allow you to move between the Source and Des-
tination screens to allow you to change values before selecting EXECUTE.

Description

Program Copy allows you to copy all the pulses in the source program to the destination
program. It may be easier to copy an existing program and modify it, than to enter a
completely new program.