beautypg.com

Output groups (cont’d), 21 pls functions – Electro Cam PL-1746 Series User Manual

Page 66

background image

4-21 PLS Functions

Description

This function allows you to divide output channels into groups, and assign operating
modes to the groups. Operating modes provide a powerful tool for relating output chan-
nel operation to sensor signals or other inputs. Incorporating modes into a control sys-
tem can greatly improve line efficiency, reduce scrap, and improve control accuracy
between machine sections at high speeds. See Section 6 for a complete explanation of
the uses and applications of operating modes.

Establishing Groups
When dividing outputs into groups, keep these rules in mind:

• Output channels are assigned to groups sequentially. Group 0 will begin with Output

0 and include the specified number of outputs; Group 1 will begin with the next output
and continue sequentially for its specified number of outputs; and so on. The last
group will automatically include all of the remaining outputs.

• You can establish as many as six groups or as few as one.

• Each group can operate in any of the six modes.

Grouping Example 1—All Outputs in One Group

Output

Includes

Group

Outputs

0

0 thru 31

Grouping Example 2—Two Groups

Output

Includes

Group

Outputs

0

0 thru 3

1

4 thru 31

Grouping Example 3—Three Groups

Output

Includes

Group

Outputs

0

0 & 1

1

2 & 3

2

4 thru 31

Also see MAIN SCREEN, GROUP OFFSET, and GRP POS DISP.

Output Groups (cont’d)