4-8 PLS Functions
Group Offset
Backplane
PL-1746 Function Name
SLC 500
Mapping Read/
Valid Range for Data
File
Index
Write
Address
Number
Capability
Group Quantity
M0:S.64
256
R/W*
1-6
Group Position Display
M0:S.65
258
R/W
0=EACH 1=ONE
Logic Inputs Status
M0:S.25
178
R/O
0-255
Group 0 Channel Count
M0:S.66
260
R/W*
0-32
Group 0 Mode
M0:S.82
292
R/W*
0-5
Group 0 Offset
M0:S.74
276
R/W
0 to (Scale Factor-1)
Group 0 Position
M0:S.16
160
R/W*
0 to (Scale Factor-1)
Group 1 Channel Count
M0:S.67
262
R/W*
0-32
Group 1 Mode
M0:S.83
294
R/W*
0-5
Group 1 Offset
M0:S.75
278
R/W
0 to (Scale Factor-1)
Group 1 Position
M0:S.17
162
R/W*
0 to (Scale Factor-1)
Group 2 Channel Count
M0:S.68
264
R/W*
0-32
Group 2 Mode
M0:S.84
296
R/W*
0-5
Group 2 Offset
M0:S.76
280
R/W
0 to (Scale Factor-1)
Group 2 Position
M0:S.18
164
R/W*
0 to (Scale Factor-1)
Group 3 Channel Count
M0:S.69
266
R/W*
0-32
Group 3 Mode
M0:S.85
298
R/W*
0-5
Group 3 Offset
M0:S.77
282
R/W
0 to (Scale Factor-1)
Group 3 Position
M0:S.19
166
R/W*
0 to (Scale Factor-1)
Group 4 Channel Count
M0:S.70
268
R/W*
0-32
Group 4 Mode
M0:S.86
300
R/W*
0-5
Group 4 Offset
M0:S.78
284
R/W
0 to (Scale Factor-1)
Group 4 Position
M0:S.20
168
R/W*
0 to (Scale Factor-1)
Group 5 Channel Count
M0:S.71
270
R/O
0-32
Group 5 Mode
M0:S.87
302
R/W*
0-5
Group 5 Offset
M0:S.79
286
R/W
0 to (Scale Factor-1)
Group 5 Position
M0:S.21
170
R/W*
0 to (Scale Factor-1)
*Not while
running
Screen
MAIN SCREEN
to CONFIG MENU
to INITIAL SETUP
to GROUP
OFFSET
GROUP OFFSET Screen—Group Mode 0, 3, 4 or 5
GRP:1< POS:
0
ABS: 132
GROUP OFFSET Screen—Group Mode 1 or 2
GRP:1< POS: 359
PRE: 30
To change the offset or position for an output group, move the cursor to GRP and then
use INC or DEC, or the numeric keypad, followed by ENT to select the group.
Enter the offset by moving the cursor to ABS (or PRE) and entering the value on the
numeric keypad, followed by ENT.
Enter the position by moving the cursor to POS and entering the value on the numeric
keypad, followed by ENT.