4-14 PLS Functions

Machine Offset

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Machine Offset

M0:S.33

194

R/W*

0 to (Scale Factor-1)

Machine Position

M0:S.24

176

R/W*

0 to (Scale Factor-1)

Resolver Position

M0:S.23

174

R/O

0 to (Scale Factor-1)

*Not while
running

Screen

MAIN SCREEN

to CONFIG MENU

to INITIAL SETUP

to

MACHINE OFFSET

MCHN POS:
MCHN OFST:

Use the INC/DEC keys, or the numeric keys followed by ENT to change MACHINE
POSITION and/or MACHINE OFFSET.

Description

Because the PL-1746 is a programmable device, it can be set to display a position of
“zero” at any point in the machine cycle. Usually, the machine is jogged to the begin-
ning of a cycle, and MACHINE POSITION is set to zero at this point. This function
eliminates the need to adjust the physical coupling between the machine and resolver
in order to change the displayed machine position. The MACHINE OFFSET can also
be set directly by entering it's value.

Set MACHINE POSITION or MACHINE OFFSET before doing any PULSE or GROUP
OFFSET programming.

Note: When direction of motion reverses, one circular unit out of 4096 will be skipped.
This prevents position transducer jitter.

See Positions & Offsets in Chapter 1.