2-5 Installation
Resolver Installation
General Information
Choose a mounting location for the resolver that allows convenient mechanical con-
nection of the resolver shaft to the machine. The resolver is normally driven at a 1:1
ratio to machine cycles, but this is not true in all applications. Commonly used methods
for driving the resolver shaft include flexible couplings, timing belts and pulleys, and
chains and sprockets. Insure that the coupling method used is tight enough to minimize
backlash without placing excessive side load on the resolver shaft.
No provision need be made for physically rotating the resolver shaft with respect to the
machine shaft. The PL-1746 can be easily programmed to set any resolver position as
the 0
°
position.
If possible, select a location that shelters the resolver from accidental mechanical abuse,
lubricants, washdown chemicals or any other liquids. Most Electro Cam resolvers have
a NEMA 4 rating or better, but avoiding contaminants will maximize their reliability and
service life.
Ambient Temperature
Electro Cam resolvers have an ambient temperature range of -40
°
to +125
°
C (-40
°
to
+257
°
F).
Resolver Wiring
Cables for non-stainless Electro Cam resolvers are shipped with one end soldered to
the resolver connector. The connector for the other end is mounted on the Plug-In
Module.
The shield is connected at both ends of the cable to prevent damage due to electro-
static discharge. If electrical noise problems are suspected when the control is in op-
eration, call Electro Cam Corp. for advice regarding shielding.
The resolver cable used with the stainless steel resolvers (PS-5300-02-XXX) does not
have a connector at the resolver end because screw terminals are used inside that
resolver. When properly connected, both ends of the cable shield will be connected. If
electrical noise problems are suspected when the control is in operation, call Electro
Cam Corp. for advice regarding shielding.
Resolver cables supplied by Electro Cam are a special type consisting of three indi-
vidually twisted/shielded pairs with a common braid shield. This insures that reliable
position information is being received by the controller. The use of other cable types
could degrade the accuracy of the position signals and make them more susceptible to
electrical noise. For these reasons, it is recommended that customers do not make
their own resolver cables. Electro Cam will make resolver cables any length up to 1000'
and can expedite shipment as required.