Rate setup, 35 pls functions – Electro Cam PL-1746 Series User Manual
Page 80

4-35 PLS Functions
Rate Setup
Backplane
PL-1746 Function Name
SLC 500
Mapping Read/
Valid Range for Data
File
Index
Write
Address
Number
Capability
Displayed Units
M0:S.51
230
R/W
0=RPM 1=BPM 2=CPM 3=IPM
Decimal Point Location
M0:S.52
232
R/W
0-3
Rate Multiplier
M0:S.53
234
R/W
1-1091
Rate Divisor
M0:S.54
236
R/W
1-63
Screen
Menu Path
MAIN SCREEN
to CONFIG MENU
to SECONDARY SETUP
to
RATE SETUP
MPY: 1< DP: 0
DIV: 1 RPM
Displayed Units
Rate Divisor
Decimal Point Location
Rate Multiplier
Units—Move the cursor to the “Units” field and use SEL to toggle between values.
MPY & DIV—Move the cursor to MPY or DIV and use the numeric keys followed by
ENT to enter a value.
DP—Move the cursor to DP and use SEL to toggle between values.
Following are a few examples of the relationships between multiplier (MPY), divider
(DIV), decimal points (DP), actual resolver speed, and displayed resolver speed:
If
And
And
Then
And a
Is
MPY
DIV
DP
MPY/DIV
Resolver
Displayed
Is…
Is…
Is…
Is…
Speed Of…
As…
1
2
0
.5
100 RPM
50 RPM
1
2
1
.5
100 RPM
5.0 RPM
1
2
2
.5
100 RPM
.50 RPM
1
2
3
.5
100 RPM
.050 RPM
1
1
0
1.0
100 RPM
100 RPM
1
1
1
1.0
100 RPM
10.0 RPM
1
1
2
1.0
100 RPM
1.00 RPM
1
1
3
1.0
100 RPM
.100 RPM
2
1
0
2.0
100 RPM
200 RPM
2
1
1
2.0
100 RPM
20.0 RPM
2
1
2
2.0
100 RPM
2.00 RPM
2
1
3
2.0
100 RPM
.200 RPM
Description
The Rate Setup function allows you to configure the RPM display on the Main Screen.