2 viewing temperature information, 3 viewing powerline information and status – Clear-Com HLI-FBS User Manual
Page 69
2)
From the third menu, select one of the following:
• Main PCB
• Slot 1 PCB
• Slot 2 PCB
• Slot 3 PCB
Note:
Slot 1, Slot 2 and Slot 3 refer to the interface module slots in the Main
Station extension bay. When looking at the rear of the module, slot 1 is the
left-hand slot, slot 2 is the middle slot, and slot 3 is the right-hand slot.
The fourth menu displays the Part number, Revision and Serial numbers for the
PCB. The format is similar to the following:
Part xxxxxx
Revision: x
Serial: x
Where x is a numerical value.
4.8.2
Viewing temperature information
To view the temperature of the Main Station:
1)
In Menu mode, select Diagnostics and then Hardware.
2)
From the third menu, select one of the following temperature sensors:
• Sensor 1
• Sensor 2
• Sensor 3
The fourth menu displays the temperature, for example:
+30°C
Environmental note:
The recommended operating temperature range for the HelixNet
HMS-4X Main Station is 0 to +40°C. The storage temperature range for the Main
Station is -30 to +70°C.
For more environmental information, see 3 Installing HelixNet Partyline.
4.8.3
Viewing powerline information and status
There are two digital partylines (Line 1 and Line 2) on the HMS-4X Main Station. Line 1 and
Line 2 are also referred to as powerlines.
Each line can support up to 10 HBP-2X beltpacks, Remote Stations or Speaker Stations.
Note:
See also
F
G
and
I
in Table 2-3 Key to Main Station/Remote Station front panel
69
HelixNet Partyline User Guide