2 viewing temperature information, 3 viewing powerline information and status – Clear-Com HLI-FBS User Manual

Page 69

background image

2)

From the third menu, select one of the following:

• Main PCB
• Slot 1 PCB
• Slot 2 PCB
• Slot 3 PCB

Note:

Slot 1, Slot 2 and Slot 3 refer to the interface module slots in the Main
Station extension bay. When looking at the rear of the module, slot 1 is the
left-hand slot, slot 2 is the middle slot, and slot 3 is the right-hand slot.

The fourth menu displays the Part number, Revision and Serial numbers for the
PCB. The format is similar to the following:

Part xxxxxx
Revision: x
Serial: x

Where x is a numerical value.

4.8.2

Viewing temperature information

To view the temperature of the Main Station:

1)

In Menu mode, select Diagnostics and then Hardware.

2)

From the third menu, select one of the following temperature sensors:

• Sensor 1
• Sensor 2
• Sensor 3

The fourth menu displays the temperature, for example:

+30°C

Environmental note:

The recommended operating temperature range for the HelixNet
HMS-4X Main Station is 0 to +40°C. The storage temperature range for the Main
Station is -30 to +70°C.

For more environmental information, see 3 Installing HelixNet Partyline.

4.8.3

Viewing powerline information and status

There are two digital partylines (Line 1 and Line 2) on the HMS-4X Main Station. Line 1 and
Line 2 are also referred to as powerlines.

Each line can support up to 10 HBP-2X beltpacks, Remote Stations or Speaker Stations.

Note:

See also

F

G

and

I

in Table 2-3 Key to Main Station/Remote Station front panel

diagram.

69

HelixNet Partyline User Guide