13.7.4

Two-wire and control connection to radio system

The two-wire connection uses a TW-47 radio interface. Because this has no power supply,
you must use an Encore Main Station to supply power. You can also use an alternative source
of power, such as a PK-7, PS-702 or PS-704.

The diagram in Figure 13-12 shows a system using an Encore Main Station.

To connect the HelixNet Partyline to a radio system using two-wire:

1)

Connect the HelixNet Partyline to the Encore Main Station. For details, see 13.1
Connecting HelixNet Partyline to Encore®.

2)

In the Modules Settings menu, select Slot n/Port A/B 2W > Channel Assign >
Channel #
to assign the 2W port to a Channel, for example Channel A.

3)

Connect the Encore Main Station to the TW-47 radio interface.

4)

Connect the TW-47 radio interface to the radio basestation.