13.5.2

Quick reference: Two-wire connection to DX210

Figure 13-7: two-wire connection to DX210

HMS-4X Main Station

Power supply

Or

Encore Main Station

(MS-70x)

DX210 Basestation (BS210)

Standard microphone cable

3-pin XLR connectors

Line must be powered (HMS-4X 2W module appears as

unpowered beltpack / Communicator to DX210).

Configure the 2W module

Configure the port as Clear-Com

Run auto-null

2W

Set Clear-Com / RTS button to Clear-Com (out position)

Connect to either intercom channel (IC1 or IC2). Press

the SELECT button for connected channel

Run auto-null using the AUTO-NULL control

Adjust In / Out levels with 2W-INPUT and 2W-OUTPUT

controls for the channel