2 quick reference: two-wire connection to dx210, Two-wire connection to dx210 – Clear-Com HLI-FBS User Manual
Page 136
13.5.2
Quick reference: Two-wire connection to DX210
Figure 13-7: two-wire connection to DX210
HMS-4X Main Station
Power supply
Or
Encore Main Station
(MS-70x)
DX210 Basestation (BS210)
Standard microphone cable
3-pin XLR connectors
Line must be powered (HMS-4X 2W module appears as
unpowered beltpack / Communicator to DX210).
Configure the 2W module
Configure the port as Clear-Com
Run auto-null
2W
Set Clear-Com / RTS button to Clear-Com (out position)
Connect to either intercom channel (IC1 or IC2). Press
the SELECT button for connected channel
Run auto-null using the AUTO-NULL control
Adjust In / Out levels with 2W-INPUT and 2W-OUTPUT
controls for the channel
Two-wire connection to DX210
136