PROGRAM STEPS
MILLPWR
Page 5-12
Operation Manual
Hole Frame and Hole Array
The frame and the array hole patterns need the same
information. Arrays have holes in the middle of the rectangular
pattern, while frames have holes only on the outside edge of
the rectangle.
Enter the rectangle’s
CENTER
and
SIZE
, and the number of
HOLES
in each direction.
The
MORE
softkey brings up fields to let you
TILT
the frame or
to enter the hole-to-hole
SPACING
.
HOLE FRAME
001
SIZE
IN X
IN Y
DEPTH
THRU
Z
ABS
CENTER
X
ABS
Y
ABS
TOOL
INCH
TYPE
HOLES
X
Y
TILT ANGLE
0° 00' 00"
HOLE SPACING
X
BETWEEN
Y
BETWEEN
CENTER
SIZE IN X
SIZE IN Y
CENTER
SIZE IN X
SIZE IN Y
FRAME
ARRAY