Symptom

Problem

Recommendation


Operator Console Displays a
Blank Screen


Brightness/Contrast Intensity is
Too Low.


Adjust Brightness/Contrast knob
located on the back of the
operator’s console.


No Power


Check that the power switch
located on the back of the operator
console is on.

Ensure that the power cord
between the operator console and
the controller cabinet is properly
connected.

Ensure that the interface cable
between the o perator console and
the controller cabinet is properly
connected.

Check that the power switch
located on the right side of the
controller cabinet and the red light
next to it is on.

Ensure that the source power
meets the specifications required
of the system and that there are no
blown fuses or tripped break-
ers. For information regarding
source power specification,
contact your ACU-RITE
MILLPWR representative.

Ensure that there is no floppy disk
in the floppy disk drive located in
the upper left corner of the front of
the operator console.



CRT failure


Contact your ACU-RITE
MILLPWR representative for
repair or replacement procedures.