DEMONSTRATION

MILLPWR

Operation Manual

Page 4-9

Now we will program the two diagonal lines. Notice that in the x-
axis the end of the first diagonal line is .750 from the beginning of
the line.

This means we can use
incremental dimensioning.

We say that “

X2

is .750

incremental from

X1

.”

Press the

LINE

key.

LINE

In the

TO

point, enter

X2 = .750

7

.

5

ABS

INC

Then press the

ABS/INC

key.

ABS

changes to

INC

, and

MILLPWR

assumes that you want to use the X coordinate

of the

FROM

point, X1, as your incremental reference.

X2 = 0.750 INC X1

Now finish the

TO

point:

Y2 = 0.000 ABS

0

USE

.750

3.00

.838

.75

TO (X2, Y2)

FROM (X1, Y1)

TO

0.750

X2

INC XI

Y2

ABS

FROM

-3.000

X1

ABS

0.838

Y1

ABS

005

LINE