Demonstration mill pwr, Operation manual – ACU-RITE MILLPWR Old Style User Manual
Page 63

DEMONSTRATION
MILLPWR
Operation Manual
Page 4-9
Now we will program the two diagonal lines. Notice that in the x-
axis the end of the first diagonal line is .750 from the beginning of
the line.
This means we can use
incremental dimensioning.
We say that “
X2
is .750
incremental from
X1
.”
Press the
LINE
key.
LINE
In the
TO
point, enter
X2 = .750
7
.
5
ABS
INC
Then press the
ABS/INC
key.
ABS
changes to
INC
, and
MILLPWR
assumes that you want to use the X coordinate
of the
FROM
point, X1, as your incremental reference.
X2 = 0.750 INC X1
Now finish the
TO
point:
Y2 = 0.000 ABS
0
USE
.750
3.00
.838
.75
TO (X2, Y2)
FROM (X1, Y1)
TO
0.750
X2
INC XI
Y2
ABS
FROM
-3.000
X1
ABS
0.838
Y1
ABS
005
LINE
To Y2