Remote storage mill pwr, Operation manual, Common error messages – ACU-RITE MILLPWR Old Style User Manual
Page 126

REMOTE STORAGE
MILLPWR
Operation Manual
Page 8-5
Common Error Messages
If the communication lines between
MILLPWR
and your PC are disrupted, an error
message will appear on the
MILLPWR
screen. Settings that do not match and a faulty
serial cable connection are the most common problems and are easiest to correct.
Error
Cause
Solution
BAUD rate
error
MILLPWR
and PC
BAUD rate settings do
not match.
Change one of the settings so that
MILLPWR
and the PC BAUD rates
are the same.
Checksum error
MILLPWR
and PC
BAUD rate settings do
not match.
Change one of the settings so that
MILLPWR
and the PC BAUD rates
are the same.
BAUD rate is too slow.
Increase the BAUD rates on both the
MILLPWR
and the PC.
No response
from PC
Serial cable connection
and COM port setting
do not match.
If the COM port setting (1 or 2) on the
PC screen does not correspond with
the port the serial cable is connected
into:
a) Change the setting; -OR-
b) Disconnect the cable from the
COM port that it is connected to
and connect it to a different COM
port.
Incorrect serial cable
Verify that you are using a serial cable
and that it is not a NULL modem
cable. Replace the cable if necessary.
MILLPWR
and PC
BAUD rate settings do
not match.
Change one of the settings so that the
BAUD rates for
MILLPWR
and your
PC are the same.