beautypg.com

Troubleshooting guide mill pwr, Operation manual, Symptom – ACU-RITE MILLPWR Old Style User Manual

Page 132: Problem, Recommendation

background image

TROUBLESHOOTING GUIDE

MILLPWR

Operation Manual

Page 9-5

Symptom

Problem

Recommendation


Table Run Away (cont.)


X and/or Y Axis Linear Encoders
Stopped Counting (cont.)


Should the linear encoder count in
certain areas only, contact your
ACU-RITE MILLPWR
representative

Should the above recom-
mendation not correct the problem,
contact your ACU-RITE
MILLPWR representative for
repair or replacement procedures.


Improper Tachometer Wire Con-
nections


Contact your ACU-RITE
MILLPWR representative for
repair or replacement procedures.


No Signal. The motor will turn
very slowly and always in one
direction.


Contact your ACU-RITE
MILLPWR representative for
repair or replacement proce-
dures.


Table Has Stiff Movement


Table is Locked


Ensure that the table is not locked.


Gibs Out of Adjustment


Refer to the machine tool manual.


No Oil in Oil Reservoir or Oil
Lines are Blocked or Discon-
nected.


Check that there is sufficient oil in
the oil reservoir.

Should the above recom-
mendation not correct the
applicable problem, contact your
ACU-RITE MILLPWR
representative for repair or
replacement procedures.


System Not Repeating or Circles
Out of Round


Machine Tool Related Problems


Ensure that the knee, ram, head
bolts, turret to column bolts and
head to knuckle bolts are properly
secured.

Check the gib adjustments (refer to
the machine tool manual).

This manual is related to the following products: