DRO

MILLPWR

Page 2-2

Operation Manual

Finding Home

The ACU-RITE’s ENC150 precision glass scales included with your

MILLPWR

system are different from standard ENC150 glass scales because they have only
one reference mark. The reference mark will be located between five and eight
inches from the centerline of your scale. The reference mark will most likely be
found in the positive count direction for both the X and Y axes; however, it may be
found in the negative count direction depending upon how the scale(s) are mounted.

MILLPWR

must find these reference marks after power-up in order to establish the

farthest table travel, so you won’t crash the table. You must find home before you
can run a program.

To find home, press the

DATUM

softkey, then the

FIND HOME

softkey. The

table will move, one axis at a time, to find the reference positions.

If the table moves until it hits the hard stops and the servo motor stops, it
means the table was already positioned past the home position. Use the
handcranks to move the table away from the end and press

FIND HOME

again. Should the

FIND HOME

softkey be pressed immediately after home has

been found, the table will move to the hard stops and the servo motors will
disengage.

After home has been found, the DRO display will change. The absolute display

shows the tool position from the most recent datum.

Once you are
familiar with where
the reference marks
are, you can use the
“MOVE TABLE”
function to get close
to them before you
press "FIND HOME".

DATUM is a term
for “workpiece
zero” or “absolute
zero”.