beautypg.com

7 show rmon alarm, Command mode, User guidelines – Planet Technology WGSW-48040 User Manual

Page 271: Example, Syntax, Default configuration

background image

User’s Manual of WGSW-24020/WGSW-48040

-27

Command Mode

User EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the alarms summary table.

Console# show rmon alarm-table

Index OID Owner

------- --------------------------------------- -----------

1 1.3.6.1.2.1.2.2.1.10.1 CLI

2 1.3.6.1.2.1.2.2.1.10.1 Manager

3 1.3.6.1.2.1.2.2.1.10.9 CLI

The following table describes the significant fields shown in the display:

Field

Description

Index

An index that uniquely identifies the entry.

OID

Monitored variable OID.

Owner

The entity that configured this entry.

5.19.7 show rmon alarm

The show rmon alarm user EXEC command displays alarm configuration.

Syntax

show rmon alarm number

ƒ

number — Alarm index. (Range: 1 - 65535)

Default Configuration

This command has no default configuration.

Command Mode

User EXEC mode

User Guidelines

There are no user guidelines for this command.

This manual is related to the following products: