15 show clock – Planet Technology WGSW-48040 User Manual
Page 182
User’s Manual of WGSW-24020/WGSW-48040
-18
Default Configuration
No servers are defined.
Command Mode
Global Configuration mode
User Guidelines
Up to 8 sntp servers can be defined.
Use the sntp unicast client enables global configuration command to enable predefined unicast clients globally.
To enable polling you should also use the sntp unicast client poll global configuration command for global enabling.
Polling time is determined by the sntp client poll timer global configuration command.
To define an SNTP server on the out-of-band port, use the out-of-band IP address format: oob/ip-address.
Examples
The following example configures the device to accept Network Time Protocol (NTP) traffic from the server on 192.1.1.1
Console (config)# sntp server 192.1.1.1
5.5.15 show clock
The show clock user EXEC command displays the time and date from the system clock.
Syntax
show clock
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the time and date from the system clock.
Console# show clock
15:29:03 Jun 17 2005