beautypg.com

9 mdix, Default configuration, Command mode – Planet Technology WGSW-48040 User Manual

Page 195: User guidelines, Example, Syntax

background image

User’s Manual of WGSW-24020/WGSW-48040

-19

Default Configuration

Flow Control is off.

Command Mode

Interface configuration (Ethernet, port-channel) mode

User Guidelines

Flow Control will operate only if duplex mode is set to FULL. Back Pressure will operate only if duplex mode is set to HALF.

When Flow Control is ON, the head-of-line-blocking mechanism of this port is disabled.

If a link is set to NOT use auto-negotiation, the other side of the link must also be configured to not use auto-negotiation.

To select auto, ensure negotiation for Flow Control is enabled.

Example

In the following example, Flow Control is enabled on e5.

Console(config)# interface ethernet e5

Console(config-if)# flowcontrol on

5.7.9 mdix

The mdix interface configuration command enables automatic crossover on a given interface. To disable automatic crossover,

use the no form of this command.

Syntax

mdix {on | auto}

no mdix

ƒ

on—Manual mdix

ƒ

auto—Auto mdi/mdix

Default Configuration

Automatic crossover is enabled

Command Mode

Interface Configuration (Ethernet) mode

User Guidelines

Mdix Auto :

All possibilities to connect a PC with cross OR normal cables are supported and are automatically detected.

Mdix ON

: It is possible to connect to a PC only with a normal cable and to connect to another switch ONLY with a cross cable.

If MDIX is set to "no mdix", the device works oppostie from the "MDIX On" behavior. It is possible to connect to PC only with

cross cable, and to connect to another switch ONLY with Normal cable