beautypg.com

2 show copper-ports tdr, Examples, Syntax – Planet Technology WGSW-48040 User Manual

Page 237: Default configuration, Command mode, User guidelines, Example

background image

User’s Manual of WGSW-24020/WGSW-48040

-23

The port under test should be shut down during the test, unless it is a combo port with an active fiber port.

The maximum disatance VCT can function is 120 meters.

Examples

The following example results in a report on the cable attached to port e3.

Console# test copper-port tdr e3

Cable is open at 100 meters

The following example results in a failure to report on the cable attached to port e4.

Console# test copper-port tdr e4

Can’t perform the test on fiber ports

5.14.2 show copper-ports tdr

The show copper-ports tdr privileged EXEC command display the last TDR (Time Domain Reflectometry) tests on specified

ports.

Syntax

show copper-ports tdr

[interface]

ƒ

interface — A valid Ethernet port.

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the last TDR (Time Domain Reflectometry) tests on all ports.

Console# show copper-ports tdr

Port Result Length Date

[meters]

------- ----------- -------------- ---------
e1 OK
e2 Short 50 13:32:00 23 July 2003
e3 Test has not been preformed
e4 Short 128 13:32:00 23 July 2003

This manual is related to the following products: