10-3 send monitor, 10-4 return monitor, 10 channel metering – Sony OXF-R3 User Manual
Page 76: Channel metering – return monitor, Channel metering – send monitor
4-16
Chapter 4
Signal Paths
Chapter 4 Signal Paths
4-10 Channel Metering
Note:
4-10-4 Return Monitor
Selecting the {RET} button at the record remotes selects the tape return as
the source, indicated by the green ‘R’ legend at the top of the Channel
Meters. In Record, the meter is automatically switched to monitor SEND.
Channel metering – Return Monitor
If both {SEND} and {RET} are selected, the SEND monitor signal takes priority.
4-10-3 Send Monitor
Selecting the {SEND} button at the channel record remotes causes the
Meter to take its source from signal being sent to tape, indicated by the
yellow ‘S’ legend at the top of the Channel Meters.
Channel metering – Send Monitor
S
D Y N
F I L T E R
2
E Q
I N S E R T
7
8
CH INPUT
MIC
GAIN
Ø
SEND
MULTI
GROUP
TRIM
M/T
SEND
ROUTING
RETURN
METER
RET
PAN
L & R
CH
OUTPUT
MAIN
CHANNEL
FADER
SEND
INPUT CHANNEL OVERLOAD
CH INPUT
MIC
GAIN
Ø
F I L T E R
2
E Q
I N S E R T
SEND RETURN
MULTI
GROUP
TRIM
RET
SEND
M/T
SEND
ROUTING
R
R
METER
D Y N
7
8
PAN
L & R
CH
OUTPUT
MAIN
CHANNEL
FADER
INPUT CHANNEL OVERLOAD