0 Version History
This chapter reports modifications and improvements over previous versions of the document.
"AT Command Set" Version MC35-ATC_01_V02.00 => MC35_ATC_01_V03.02
Chapter
Page
AT command
What is new
Note regarding sequential order of concatenated commands added.
AT+CBST
Command syntax corrected: Parameter
mandatory.
AT+CCFC
New
AT+CFUN
SLEEP mode described in greater detail
AT+CLCK
New
AT+CPIN
Timing algorithm of incorrect password corrected
AT+CSQ
Note added: Realistic BER values can be obtained
only if there is a call in progress.
AT+CPMS
Difference between SM, ME and MT storage ex-
plained.
AT^SGAUTH
New command to specify protocol for PPP authenti-
cation
AT^MONI
Channel numbers are now issued in the form of 4-digit
numbers. Therefore, the examples on page 169 have
been updated.
Frequency hopping will now be indicated with “h” (in-
stead of the previously used “0”.
Notes modified: If during a connection the radio cell is
changed, the parameters LAC, Cell, NCC BCC, PWR
and RXLev of the ‘Serving Cell’ part will not be up-
dated.
AT^SCKS
Presentation mode of the ^SCKS URC will be saved
upon MC35 restart.
Notes regarding empty SIM card tray modified.
AT^SCTM
Chapter revised due to improved presentation of tem-
perature shutdown URCs.
AT+CXXCID
AT^SCID
AT^SGAUTH
Both commands now independent of PIN authentica-
tion
Command added to list of PIN independent com-
mands
Lists of result codes restructured.
*# codes
Chapter revised. Further examples added.