for SMS-COMMANDs:
+CMGL: ,,,[
+CMGL: ,,,[...]] OK

for CBM storage:
+CMGL: dex>,,,,,[
+CMGL: ,,,,,
[...]]OK

2) If PDU mode (+CMGF=0) and command successful:
+CMGL: ,,[],
[+CMGL: ,,[alpha],
[...]] OK

for CBM storage:
+CMGL: ,

3) If error is related to ME functionality:
+CMS ERROR:

Parameter

string type alphanumeric representation of or corre-

sponding to the entry found in phonebook; implementation of this
feature is manufacturer- specific

GSM 03.40 TP-Command-Type in integer format (default 0)

GSM 03.40 TP-Destination-Address Address-Value field in string
format; BCD numbers (or GSM default alphabet characters) are
converted into characters; type of address given by


In case of SMS: GSM 03.40 TP-User-Data in text mode responses; format:

- if

indicates that GSM 03.38 default alphabet is used and indi-

cates that GSM 03.40 TP-User-Data-Header-Indication is not set:
ME/TA converts GSM alphabet into current TE character set ac-
cording to rules of Annex A

- if

indicates that 8-bit or UCS2 data coding scheme is used, or

indicates that GSM 03.40 TP-User-Data-Header-Indication is set:
ME/TA converts each 8-bit octet into hexadecimal numbers con-
taining two IRA characters (e.g. octet with integer value 42 is
presented to TE as two characters 2A (IRA 50 and 65))

In the case of CBS: GSM 03.41 CBM Content of Message in text mode re-
sponses; format:

- if >indicates that GSM 03.38 default alphabet is used: ME/TA con-

verts GSM alphabet into current TE character set according to
rules of Annex A

- if indicates that 8-bit or UCS2 data coding scheme is used: ME/TA

converts each 8-bit octet into hexadecimal numbers containing
two IRA characters